How to check your installation
opening of movable wall
Measure the opening height at both
ends and at 2-3m distances in the track line.
Make sure
that:
-
End walls are
plumb. If this is not the case check whose responsibility it is to make them
plumb. In the head the possible straightening may be achieved by adjustable
aluminum joint profiles. Make sure that the adjustment is big enough. At the
telescopic panel end check if some adjustment lath or corresponding is needed on
the permanent wall.
-
Floor is
level and flat enough
-
Structure
where track is fixed to is durable enough
-
There will be
nothing (e.g. air ducts or cable ladders) to be installed in the track line or
in the storage area that could restrict track
installation.
Make sure that storage
area:
-
Height is at
least the same as in that movable wall line
-
The track
line planned to the storage area is clear. (No projections hindering panel
movements beside the permanent wall).
If you have any additional
questions about installation opening of movable walls, please contact Movable
Wall team using our contact form.
Request more